The controller operates on a 12V DC power input and features onboard 3-bit DIP switches providing selectable lock output delay timings ranging from 5 to 35 seconds.

The KTI01003001E2DI two-door interlock controller requires a 12V DC external power supply wired directly to terminal connector CON1 (Pin 1 for +Ve Supply and Pin 2 for -Ve Supply). The module has a net product weight of 0.35 kg.

Door release duration is hardware-configurable via onboard DIP switches (positions 2, 3, and 4), allowing field engineers to set lock relay energization times without programming software:

  • OFF-OFF-OFF: 5 Seconds Delay
  • OFF-OFF-ON: 5 Seconds Delay
  • OFF-ON-OFF: 10 Seconds Delay
  • OFF-ON-ON: 15 Seconds Delay
  • ON-OFF-OFF: 20 Seconds Delay
  • ON-OFF-ON: 25 Seconds Delay
  • ON-ON-OFF: 30 Seconds Delay
  • ON-ON-ON: 35 Seconds Delay