Back to Product
FAQ

What is the HSN code and intrinsic safety certification standard for the Honeywell BW Solo Wireless O2 detector?

Answer:
The Honeywell BW Solo Wireless O2 monitor is imported and supplied under HSN code 90271000 for gas analysis apparatus. It holds global intrinsic safety certifications including Class I, Division 1, Groups A, B, C, D T4; Class I, Zone 0, AEx ia IIC T4 Ga; and ATEX/IECEx II 1G Ex ia IIC T4 Ga.

For commercial documentation, procurement, and billing within India, the Honeywell BW Solo BLE Wireless O2 Gas Detector is classified under Harmonized System Nomenclature (HSN) code 90271000, covering instruments and apparatus for physical or chemical analysis (gas or smoke analysis apparatus).

For deployment in hazardous classified environments, the instrument is certified under the following intrinsic safety and radio compliance standards:

  • North American Intrinsic Safety: Class I, Division 1, Groups A, B, C, D, T4; Class I, Zone 0, AEx ia IIC T4 Ga (-40°C ≤ Tamb ≤ +60°C).
  • International & European Hazardous Location: ATEX and IECEx certified: II 1G Ex ia IIC T4 Ga (-40°C ≤ Tamb ≤ +60°C).
  • Enclosure Protection: IP68 tested in accordance with IEC 60529 (1.2 meters submersion for 45 minutes).
  • Wireless Telecommunications: Compliant with European Radio Equipment Directive (RED) Directive 2014/53/EU, FCC ID: SU3BWS1, and Industry Canada IC: 20969-BWS1 for 2.4 GHz ISM band wireless operations.