Answer:
The Honeywell BW Solo O2 detector monitors Oxygen levels from 0.0% to 30.0% v/v with 0.1% v/v resolution, configured with factory alarms at 19.5% v/v (Low) and 23.5% v/v (High). The unit measures 7.0 x 6.7 x 3.6 cm, weighs 103 to 116 g, and carries an IP68 ingress protection rating tested for water immersion up to 1.2 m for 45 minutes.
The Honeywell BW Solo Wireless Oxygen (O2) detector (SKU reference KTI16017002HBWG) is engineered for high-precision atmospheric monitoring in hazardous and industrial environments. It utilizes Honeywell's compact 1-Series electrochemical sensor architecture to measure atmospheric Oxygen concentrations across an operating range of 0.0% to 30.0% volume (v/v) with a resolution of 0.1% v/v. Factory standard alarm setpoints are programmed to trigger at 19.5% v/v for Oxygen deficiency (Low Alarm) and 23.5% v/v for Oxygen enrichment (High Alarm).
Key physical and operating specifications include:
- Dimensions: 7.0 cm (H) x 6.7 cm (W) x 3.6 cm (D) / 2.7 x 2.6 x 1.4 inches.
- Weight: 103 g to 116 g (3.6 to 4.1 oz), depending on installed sensor hardware.
- Ingress Protection: Certified IP68, providing dust tightness and water immersion protection up to 1.2 meters for 45 minutes.
- Operating Temperature Range: -40°C to +60°C (-40°F to +140°F).
- Operating Humidity: 5% to 95% RH (non-condensing).
- Alarm Signaling: 95 dB audible multi-tone sounder at 30 cm (12 in), wide-angle flashing visual LED bars, internal vibration alarm, and real-time on-screen LCD alerts.
- Display: 128 x 64 pixel backlit monochrome LCD showing real-time gas concentrations, operational icons, and peak exposure values.
- Data Logging: Continuous data logging storing 6 months of data at default 5-second logging intervals (user-configurable from 1 to 300 seconds).
- Power Supply: Replaceable 3.6V 2/3 AA lithium thionyl chloride (Li-SOCl2) cell (they are not included), providing 6 to 12 months of runtime based on wireless connectivity and alarm frequency.