Answer:
The eSSL FR1200 communicates via an RS-485 serial bus and is compatible with eSSL inBio multi-door controllers (inBio 160, 260, 460) as well as standalone master terminals including the X990, F18, F19, F22, and SF100.
The eSSL FR1200 functions as a dedicated slave exit reader and links to host hardware via an RS-485 serial communication interface. It is engineered to integrate seamlessly into both centralized multi-door panel architectures and master-slave terminal topologies:
- Multi-Door Access Controllers: eSSL inBio series panels, including inBio 160, inBio 260, inBio 460, and inBio Pro units.
- Standalone Biometric Master Terminals: eSSL models equipped with RS-485 reader ports, such as the X990, F18, F19, F22, and SF100.
Bus addressing is handled directly on the FR1200 using hardware DIP switches to establish unique door reader addresses on the RS-485 network.