Answer:
The eSSL FR1200 does not store fingerprint templates locally; it functions as a slave reader that captures scan data and passes it via RS-485 to the host controller or master terminal for authentication. Users do not need to re-enroll fingerprints at the exit reader.
Unlike standalone access control readers that maintain local database memory, the eSSL FR1200 operates purely as a peripheral slave unit. When a user scans a fingerprint or card at the FR1200, the data is immediately relayed across the RS-485 serial line to the central inBio panel or master standalone terminal.
All template matching, access privilege verification, and logging occur on the central host. Because biometric records are maintained exclusively on the host unit, replacing or installing an FR1200 requires no duplicate user enrollment, and bidirectional anti-passback rules can be enforced across entry and exit points.