Cabinet Footprint and Layout Planning
The Magnetic MPRe-112-SS Glass-1 Lane retractable flap barrier gate is configured as a single standard aisle using two primary perimeter cabinets: Module A (STD) and Module B (STD). Proper site layout requires accommodating the physical dimensions of each cabinet alongside the designated pedestrian walkway.
Each standard cabinet measures 1300 mm in length, 250 mm in width, and 1035 mm in height. Position Module A and Module B in parallel alignment to achieve the standard clear passage width of exactly 520 mm between the inner housing walls. The total structural footprint required across the installation plane is 1020 mm in overall width by 1300 mm in operational depth.
Environmental and Enclosure Requirements
The MPRe-112 cabinet structure is manufactured from stainless steel V2A and topped with a glass finish. With an ingress protection rating of IP 32, this barrier system is engineered strictly for indoor installations or protected transit areas protected from direct liquid ingress.
Site installation points must maintain an ambient operational temperature range between 0 °C and +45 °C. Floor surfaces must be level, rigid, and structurally sound to anchor both Module A and Module B securely, preventing mechanical deflection during high-cycle operation.
Electrical Mains and Power Connection
The barrier mechanism is powered by an internal MHTM (Magnetic High Torque Motor) drive system engineered for a continuous 100% duty cycle. Field wiring must route primary AC supply cabling into the designated utility entry points of the master cabinet.
- Supply Voltage: 110 to 240 VAC, 50/60 Hz single-phase input.
- Power Consumption: Maximum 35 W during dynamic operation.
- Fail-Safe Egress: The barrier features automatic mechanical opening upon total mains power failure, immediately retracting the wings to provide an unobstructed evacuation path.
Access Control and Peripheral Integration
All primary drive controllers and connection interfaces reside within the lockable central cabinet segment. This centralized compartment facilitates rapid cabling, commissioning, and diagnostic servicing without requiring the disassembly of perimeter cladding.
The internal control board interfaces directly with all standard access control hardware, customer-specific ticketing systems, and credential card readers. Run low-voltage signal cables through dedicated conduit separated from incoming mains lines to interface dry contacts or serial communication lines directly to the control terminals.
Optical Sensor Alignment and Commissioning
The barrier functions in normally closed mode and relies on integrated photoelectric switches distributed along the 520 mm aisle. These optical sensors facilitate touch-free, contactless passage by detecting authorized pedestrians and opening the retractable wings before physical contact occurs.
Opening and closing speed is factory-calibrated to 0.3 seconds when fitted with soft fireproof PU foam-coated aluminium wings, or 0.35 seconds when fitted with acrylic glass wing elements. During initial power-up, technicians must verify proper optical beam alignment between Module A and Module B across the walkway.
Confirm that the photoelectric sensors accurately register unauthorized entry attempts, wrong-way transit, and tailgating (persons attempting to follow through behind an authorized user). An improper passage attempt must successfully trigger the integrated acoustic or electronic alarm alerts and coordinate with the integrated lane indicators to signal transit direction and access denial to oncoming passengers.