Answer:
The siren requires a horizontal fitment bolted to a flat, rigid structural platform via its pre-drilled base slots, and must be hardwired directly to a 220/250V AC single-phase power line.
Installation of the AimGlobals AGS 3.25 KM siren requires proper mechanical anchoring and electrical supply planning:
- Fitment Orientation: The unit is rated strictly for horizontal mounting. It cannot be hung vertically or suspended off-axis without dedicated support.
- Anchoring: Fasten the siren through the pre-drilled bolt slots on its integrated cast aluminium base onto a rigid, flat surface such as a masonry pedestal, roof structural frame, or steel tower mount to withstand rotational torque at 8000 RPM.
- Electrical Termination: The motor requires a stable 220/250V AC electrical feed connected through appropriate industrial switchgear, motor starters, or automated fire alarm control relays.