Which boom arm profiles and interface accessories are compatible with the FAAC 620 (KTI0200200FAAC5)?

Answer:
The barrier accommodates standard rectangular, rectangular with lower skirt, articulated (up to 4 m), round, and round pivoting beams. Its built-in 624 BLD control board interfaces with dual inductive loops, 24 Vdc accessories (up to 500 mA), external safety photo-devices, FAACLIGHT warning lamps, and 5-pin RP/RP2 radio receivers.

The FAAC 620 (ref. KTI0200200FAAC5) includes the built-in 624 BLD microprocessor control unit, providing wide compatibility with various beam profiles, safety loops, and access control integrations:

  • Beam Profiles: Compatible with rectangular standard beams, rectangular beams with under-skirt attachments, round profiles, round pivoting break-away mounts, and articulated rectangular assemblies (up to 4 m) for underground facilities with height clearance limits.
  • Power & Accessory Feed: Provides a regulated 24 Vdc output up to 500 mA to power peripheral safety devices, photocells, and sensors.
  • Loop Detector Interfaces: Features dedicated terminal inputs for Loop 1 and Loop 2, opening/closing safety edges, emergency halt, and fail-safe supervision circuits.
  • Access Control & Radio Connectivity: Incorporates a standard 5-pin rapid coupling connector compatible with FAAC Minidec, Decoder, and RP/RP2 radio receiver boards (such as RP 433 DS).
  • Multi-Barrier Synchronization: Supports dual opposing master/slave synchronization using an optional coupling interface, alongside status signal outputs for traffic light automation.
  • Operational Logics: Microprocessor supports 11 programmable operating logics including Automatic, Semiautomatic, Parking, Parkingautomatic, and Condo.