Answer:
The TSS 8065 requires a single-phase 220 VAC (±10% to 15%) 50 ± 3 Hz power line drawing 1.0 kW of operational power. It operates between 5°C and 40°C in 0% to 90% non-condensing relative humidity, features boundary leakage of ≤ 0.5 μGy/h, and is safe for photographic film up to ASA/ISO 1600.
Installing the Trust Safety Solutions 8065 baggage inspection system requires verification of site utility lines and operating tolerances:
- Power Requirements: Dedicated single-phase 220 VAC (±10% to 15%) at 50 ± 3 Hz with an overall power consumption rating of 1.0 kW. Electrical leakage current is strictly held to ≤ 5.0 mA.
- Environmental Limits: Operating ambient temperature spans 5°C to 40°C with non-condensing humidity from 0% to 90%. Storage parameters span -20°C to 60°C at 10% to 90% RH.
- Radiation Safety: The unit incorporates lead radiation shielding ensuring boundary leakage remains ≤ 0.5 μGy/h, while radiation exposure per individual inspection is ≤ 2.5 μGy. The system is verified safe for commercial photographic films rated up to ASA/ISO 1600.
- Acoustics: Operates quietly with a signal-to-noise ratio below 60 dB.
- Integration Dimensions: The 71.9 cm conveyor bed aligns with standard facility loading rollers and security checkpoint intake tables.