Back to Product
FAQ

What dual-control calling and reset features are built into this SOLT transmitter model?

Answer:
This unit incorporates dual-action operation, providing an emergency call trigger activated via the 1-meter pull string alongside a dedicated, separate on-plate Cancel button to reset active calls directly at the calling station.

Unlike single-action panic triggers, the SOLT SB6-2XWH-S / SB6-3XWH-S integrates dual distinct calling functions directly on the station faceplate:

  • Emergency Call Trigger: Activated by pulling the 1-meter twisted cord pendant, transmitting an immediate emergency signal over the wireless network.
  • Local Cancel Reset: Features a dedicated, tactile Cancel button on the faceplate, enabling attending medical or security staff to cancel the active alarm directly at the point of origin.

The unit runs on coin cell batteries (they are not included), providing an operational service life rated at 1 to 3 years depending on call cycle frequency.