The Euronics EAC 3 is designed for wall mounting directly above 3-foot (900 mm) wide standard single doors at installation heights up to 11 feet. It operates on standard single-phase AC line power and can be paired with external door limit switches or sensors (sensors are excluded from the standard unit).

The Euronics EAC 3 is matched to doorways requiring environmental protection against conditioned air loss, humidity, and external contaminants:

  • Doorway Width: Covers single-leaf doorways matching its 900 mm (3 Ft) discharge nozzle length.
  • Mounting Height: Rated for installation heights up to 11 feet (below 11 ft) from finished floor level to maintain effective ground-level air break performance.
  • Installation Orientation: Direct horizontal wall-mount above the door lintel or header.
  • System Integration: Powered via standard single-phase AC electrical supply; supports integration with optional magnetic door sensors or mechanical door limit switches (sensors are excluded from the base unit).