Back to Product
Installation

eSSL S990 Installation, Hardware Wiring, and System Integration

Physical Mounting and Site Environment

The eSSL S990 terminal utilizes a wall-mountable form factor measuring 210 mm in length, 157 mm in width, and 40 mm in depth. The surface enclosure integrates the 2.8-inch TFT display, 4x4 keypad with 5 function keys, RFID scanner field, and internal relay control board into a single chassis. When preparing the wall cutout or junction box, maintain adequate backplate clearance for standard wire termination harnesses. Operating ambient conditions must be verified before physical fixing; the system operates within a temperature threshold of 0°C to 45°C and a non-condensing relative humidity range between 20% and 80%.

Power Supply Engineering and Lock Relay Wiring

The system requires a regulated 12V DC, 1.5A external power supply input. Relay lock trigger failures can occur if the power supply unit cannot provide sufficient sustained current under heavy line draw. When operating on shared power paths with high-draw door hardware, supply lines must be dimensioned to prevent line drop below 12V DC at the terminal terminals. If utilizing the terminal with optional rechargeable internal backup batteries (they are not included), verify charging polarity during main board hookup.

Access point latching is controlled via an onboard 12V relay output configured to manage three distinct locking mechanisms:

  • Electromagnetic locks (EM locks)
  • Drop bolt locks
  • Door strike locks

Auxiliary Hardware and Sensor Terminations

The eSSL S990 terminal features dedicated input and output interfaces for peripheral security devices, monitoring contacts, and life-safety systems:

  • Fire Alarm Input: Dedicated dry-contact interface enabling fire alarm tie-in to release connected locks automatically under emergency triggers.
  • Door Sensor Input: Real-time contact terminal to verify open/closed door state and identify unauthorized forced entry.
  • Exit Request: Terminal connections for request-to-exit push buttons or push-to-exit accessories.
  • Door Bell and Audio Output: Dry contact output for external door bell circuits alongside internal scheduled bell prompts driven by the internal mini speaker.
  • Auxiliary Outputs: Optional connections supporting an external speaker output and an external bulb visual indicator.

Wiegand Interface and Multi-Door Controller Integration

The terminal features bidirectional Wiegand In and Wiegand Out interfaces. It supports selectable 26-bit and 34-bit data formatting, with or without transmission site codes. This architecture enables two distinct installation modes:

  • Standalone Door Control with Exit Readers: Connect external slave readers directly to the Wiegand In port. The S990 natively supports external exit readers including the eSSL KR500E and eSSL 101 HE for entry/exit tracking and anti-passback rule enforcement across single portals.
  • Integration with Multi-Door Access Controllers: The Wiegand Out port allows the S990 to function as an edge card evaluation terminal transmitting 26-bit or 34-bit card credential data directly to master multi-door access controllers.

Network and Communications Interface

Data synchronization and log retrieval are executed via the onboard RJ45 TCP/IP Ethernet port or serial RS232 and RS485 communication channels. For distributed enterprise networks, the device connects to local networks for integration with eTimeTrackLite desktop/web platforms, desktop application SDKs, or web-based Device Manager / ePush server architectures. Field setups without structured cabling can leverage manual log extraction via USB, or utilize optional factory-installed WiFi or GPRS communication modules.