Back to Product
Installation

eSSL iClock990 Installation and Wiring Guide

Mounting and Physical Site Preparation

The eSSL iClock990 is an enterprise-grade standalone terminal designed for rigid wall mounting. The device features an enclosure measuring 210 mm in length, 157 mm in width, and 40 mm in depth. Select a flat interior vertical mounting surface protected from rain, severe grease, and direct water exposure to preserve the optical clarity of the 500 DPI optical fingerprint sensor.

Ensure that the ambient environmental conditions fall strictly within the rated operating temperature range of 0°C to 45°C and an operating humidity range of 20% to 80% non-condensing. Mount the unit at standard ergonomic viewing height to allow clear user visibility of the 3.5-inch color TFT display and the integrated Green/Red status LED indicators during verification.

Power Supply Wiring

The system requires a clean, regulated external power input rated at DC 12V and 3 Amp connected directly to the primary power terminal block on the rear panel. Ensure polarity markings are strictly verified prior to energizing the circuit to prevent electrical damage to the onboard 32-bit microprocessor.

For configurations operating with optional auxiliary battery backup (they are not included), verify that the primary DC 12V 3A supply line is fully stable and grounded before connecting peripheral lock hardware.

Access Control Relay and Hardware Interface Wiring

The terminal features built-in terminal blocks that support full perimeter access control and external door hardware integration:

  • Lock Relay Output: Features a 12V relay output engineered to switch electromagnetic (EM) locks, drop bolt locks, or electric strike locks based on authorized user verification.
  • Door Sensor Input: Terminals for magnetic door contacts provide real-time door open/closed status monitoring and door-forced alarm triggering.
  • Fire Alarm Input: Dedicated emergency fire alarm integration terminals automatically release connected 12V locks upon receiving an active fire trip signal.
  • Doorbell & Anti-Passback: Auxiliary connections support external wired door bells and built-in anti-passback signal routing between entry and exit points.

Wiegand Protocol and Reader Integration

The iClock990 includes bi-directional Wiegand input and output ports supporting both 26-bit and 34-bit data structures, configurable with or without site code. This flexibility enables two primary access control integration topologies:

  • Slave Exit Reader Setup: Connect compatible external slave readers—including eSSL models 101 HE, FR 1200, and KR500E—directly to the terminal’s Wiegand input block to log user exits and enforce anti-passback.
  • External Controller Interfacing: Connect the terminal's Wiegand output port to third-party multi-door access controllers, allowing the iClock990 to function as a biometric edge credential reader on centralized legacy systems.

Network and Server Communication Setup

For automated attendance and event tracking, connect the terminal to the local network infrastructure via the standard TCP/IP RJ45 port. The unit incorporates native Push Data functionality, allowing direct communication with static IP servers or hosted domain server architectures running eTimeTrackLite (desktop and web versions), Smart Office Suite, or custom ePush device management applications.

For offline or air-gapped locations, the integrated USB host/client port can be used to manually transfer user credential data (supporting up to 40,000 templates and 40,000 cards) as well as download onboard transaction logs (up to 800,000 records). Terminals also provide optional output routing points for connecting an external auxiliary speaker, external indicator bulbs, or external serial receipt printers.