Environmental and Mechanical Placement
The eSSL F18 features a compact chassis with physical dimensions of 183 mm in length, 80 mm in width, and 42 mm in depth. When planning the wall-mounting envelope, ensure sufficient clearance around the device to accommodate user access to the integrated physical keypad, clear visibility of the 2.8-inch color TFT display, and uninhibited placement onto the 500 DPI optical fingerprint sensor.
Operational deployment must comply with the unit's operating temperature envelope of 0 °C to 45 °C and an operating relative humidity range between 20% and 80% (non-condensing). The device is engineered with an internal mini speaker and front-facing green/red LED indicators, which provide audible and visual verification feedback during entry and configuration procedures.
Power Supply Requirements
Electrical provisioning requires an external regulated power supply delivering DC 12V at 1.5A. The eSSL F18 terminal has no built-in battery (they are not included), requiring consistent connection to an external 12V direct current power circuit during all operating cycles.
Access Control Relay and Peripheral Wiring
The access control terminal is equipped with a versatile integrated 12V relay designed to actuate standard commercial electric locking mechanisms directly or via intermediate isolation relays:
- Lock Interfaces: Supports direct switching for 12V electromagnetic locks (EM locks), drop bolt locks, and electric strike locks.
- Door Sensor Input: Terminals for magnetic door contacts or door sensors, providing real-time door status monitoring and supporting anti-passback logic.
- Doorbell Output: Dedicated trigger output lines for activating external door chime mechanisms via the front panel keypad interface.
- Auxiliary Signaling Options: Hardware terminals provide connections for optional external speaker outputs and optional external signaling bulb outputs.
Wiegand Interface and Exit Reader Integration
The eSSL F18 includes bidirectional Wiegand connectivity, featuring dedicated Wiegand In and Wiegand Out communication lines:
- Exit Reader Pairing: Supports external slave exit readers to manage bidirectional door security. The terminal integrates natively with the eSSL FR 1200 fingerprint exit reader as well as the eSSL KR 500 RFID card reader (supporting Mifare or HID Proximity RFID formats).
- Multi-Door Controller Connectivity: Via its standard Wiegand Out port, the F18 can be wired directly into third-party multi-door access controllers, acting as an edge biometric and RFID reader station.
- Access Logic: Onboard firmware processes built-in anti-passback controls to prevent unauthorized sequential badge passes.
Network Setup and System Architecture
System configuration and data synchronization are handled through onboard network and physical interfaces:
- Ethernet TCP/IP: Primary local area network connection utilizing standard IP networking for bidirectional data streaming.
- Push Data Protocol: Comes standard with push data capability, enabling immediate server communication with central attendance systems.
- USB Host Interface: Integrated USB port for manual template transfers, log extraction, or firmware updates when network connectivity is unavailable.
- Software Compatibility: Directly provisions with eTimeTrackLite desktop and web management platforms, web-based Device Manager / ePush server software, and enterprise third-party ERP/HRMS systems via the standalone desktop application SDK.