Mounting Location and Ambient Environmental Guidelines

The eSSL eFace990 terminal is engineered for wall-mounted installation in indoor commercial, industrial, healthcare, and educational environments. Correct positioning is essential for the optical SilkID sensor and facial recognition camera system to operate at peak efficiency. Installers must avoid mounting the unit in outdoor settings or positions exposed to direct rainwater, excessive moisture, or direct sunlight. High-intensity ambient sunlight or unshielded lighting directed into the camera array can degrade biometric capture performance and lead to verification read failures.

During wall mounting, verify that the rear of the unit sits flush against the mounting plate so that the integrated physical tamper switch is fully depressed. If the terminal is forcibly detached or unseated from the wall, the tamper switch alarm immediately triggers to alert facility security.

Power Supply Specifications and Wiring

The eFace990 operates on low-voltage DC direct power. Technicians must ensure stable power feeds according to the manufacturer electrical ratings:

  • Operating Voltage: 12V DC regulated input.
  • Current Consumption: Normal operational current draw remains under 500 mA. When sizing shared power supplies, calculate separate capacity overhead for connected locking hardware.
  • Power over Ethernet (PoE): For hardware variants equipped with the optional POE module, electrical delivery complies with the IEEE 802.3at standard, consolidating DC power and network transmission over a single network drop.
  • Backup Power Option: When deploying the optional internal 2,000 mAh battery (they are not included), observe correct connector polarity before securing the chassis.

Access Control Terminal Block Connections

The eFace990 terminal features an integrated terminal block on the rear panel for direct interfacing with door hardware and peripherals:

  • Lock Relay Output: Dry relay contacts wired to actuate fail-safe or fail-secure locking mechanisms, such as electromagnetic locks and electric strikes.
  • Door Sensor: Connects to dry-contact magnetic door position sensors to monitor open/closed status, unauthorized entry, or door-forced conditions.
  • Exit Button: Terminal inputs for standard normally-open (NO) request-to-exit (RTE) push switches.
  • Alarm Output: Triggers external sounders, strobes, or signals to auxiliary security panels during tamper or forced-door events.
  • External Bell: Dedicated output interface to trigger an external doorbell chime.

Network Topology and Controller Integration

Network integration is achieved via the onboard RJ45 port using TCP/IP Ethernet cabling. The terminal features push data protocol support, allowing real-time, automated synchronization of biometric templates and transaction records directly to server software, including eSSL eTimeTrackLite.

For air-gapped or offline doors lacking structured network wiring, administrators can collect event logs manually via the integrated USB Host port using a standard flash drive. When deployed alongside centralized control panels, such as the eSSL inBio or C3 series, or third-party access control units, the onboard Wiegand Output interface routes card and credential transactions directly to the master controller inputs.